<<< Back

MODELS

Numa DM 30

Numa  DM60

Numa DM80

Numa DM100

Resin Qty.

30 Ltr

60 ltr.

80 ltr.

100 ltr.

OBR  @ 100 ppm ionic Load

12,000 ltrs

24,000  ltrs.

32,000 ltrs.

40,000 ltrs

Min. Working  Pr.

2.0Kg/cm²

2.0 Kg /cm²

2.0 Kg /cm²

2.0 Kg/cm²

Max. Working Pr.

4.0Kg/cm²

4.0 Kg /cm²

4.0 Kg /cm²

4.0 Kg/cm²

Vessel

FRP

FRP

FRP

FRP

Resin Make 

Thermax    

Thermax  

Thermax    

Thermax    

Reagenerant Qty Acid  &  Alkali       

HCL / 9 Kg
NaOH / 3 Kg

HCL / 18 Kg
NaOH / 6  Kg

HCL / 24 Kg
NaOH / 8 Kg

HCL / 30 Kg
NaOH / 10 Kg

Type  of  Valve

20NB

      20 NB

20 or  25 NB

25 or 40NB TM

Max. Flow Rate. m3/Hr

1.5 m3 / Hr.       

1.5 m3 / Hr.       

1.5 m3 / Hr.       

2.5 m3 / Hr         


MODELS

Numa DM 150

Numa  DM200

Numa DM250

Numa DM330

Resin Qty.

150 Ltr

200 ltr.

250 ltr.

330 ltr.

OBR  @ 100 ppm ionic Load

60,000 ltrs

80,000  ltrs.

1 Lacs  ltrs.

1.32 Lacs ltrs

Min. Working  Pr.

2.0Kg/cm²

2.0 Kg /cm²

2.0 Kg /cm²

2.0 Kg/cm²

Max. Working Pr.

4.0Kg/cm²

4.0 Kg /cm²

4.0 Kg /cm²

4.0 Kg/cm²

Vessel

FRP

FRP

FRP

FRP

Resin Make 

Thermax    

Thermax  

Thermax    

Thermax    

Reagenerant Qty Acid  &  Alkali       

HCL / 45 Kg
NaOH / 15 Kg

HCL / 60 Kg
NaOH / 20 Kg

HCL / 75 Kg
NaOH / 25 Kg

HCL / 100 Kg
NaOH / 35 Kg

Type  of  Valve

25 or 40 NB TM

40 NB TM

40 NB SM

40 NB SM

Max. Flow Rate. m3/Hr

3 m3 / Hr.       

3 m3 / Hr.        

3 m3 / Hr

 4 m3 / Hr            


MODELS

Numa DM500

Numa DM 750

Numa  DM1000

Resin Qty.

 500 ltr.

750 Ltr

1000 ltr.

OBR  @ 100 ppm ionic Load

2 Lacs ltrs.

3 Lacs  ltrs

4 Lacs   ltrs.

Min. Working  Pr.

2.0 Kg /cm²

2.0Kg/cm²

2.0 Kg /cm²

Max. Working Pr.

4.0 Kg /cm²

4.0Kg/cm²

4.0 Kg /cm²

Vessel

FRP

FRP

FRP

Resin Make 

Thermax    

Thermax  

Thermax  

Reagenerant Qty Acid  &  Alkali       

HCL / 150 Kg
NaOH / 50 Kg

HCL /225 Kg
NaOH / 75 Kg.  

HCL / 300 Kg NaOH /100 Kg

Type  of  Valve

40 NB SM

40 NB SM

   40 NB SM

Max. Flow Rate. m3/Hr

  4 m3 / Hr.

2.0Kg/cm²

2.0 Kg /cm²


Note  :- 
Inlet  Water  should  be  colourless  free  from  turbidity, oil, grease, Organic  Matter.
Treated   water  quality  depends  on  Raw  Water  Analysis.
<<< Back